1st Level Regulators Tank to Line. Fisher First Stage Regulators.
1 The regulator being shielded by means of a suitable cover such as the tank dome pictured above or 2 The regulator being installed with the vent facing down if installed without a cover.
1st stage propane regulator. First Stage Regulators First stage regulators are used at the tank to reduce the pressure to 10 psi. They are always used in conjunction with a second stage regulator at the house or appliance. Marshall 1122H-AAJ First Stage Propane LP Regulator 10PSI Output 14 x 12 14 Female NPT Input - 12 Female NPT Output10 PSI OutputAdjustable Output.
8 - 12 PSI1000000 BT. First stage regulators are installed at the propane tank connected directly to the service valve with a pigtail. If a primary level regulator is used in an LP gasoline plumbing work program a second period regulator needs to be installed downstream.
In other words an initial stage regulator can not be setup individually in an LP gasoline system. There should be a second stage regulator set up nicely. 1st stage regulator will compensate for varying container demands and can deliver to the gas range at a pressure of 10 pounds or much less.
The goal of an initial stage regulator should provide propane at an ample stress to a downstream next period regulator. The first stage propane regulator will compensate for differing tank pressures and will deliver into the gas line at a pressure of 10 pounds or less. The purpose of a first stage propane regulator is to deliver propane at an ample pressure to a downstream second stage propane regulator.
This First Stage Propane Regulator supplies a flow rate of 2750000 btus. It is manufactured by Marshall Excelsior a leader in the industry. Inlet FPOL Outlet 34 FNPT BTU 2750000 Pressure 10 psi MFG Part MEGR-1622H-JGJ.
1000000 btu Compact First Stage Propane Regulator These compact first stage regulators are designed perfectly for tight applications such as underground tank domes. They feature an adjustment range from 9 12 psi factory set at 10 psi stainless steel internal components fluororcarbon FKM seat discs molded lip fabric reinforced. 2750000 btu First Stage Propane Regulator MEGR-1622H-JGJ feature an adjustment range from 9-12 PSIG factory setting is 10 PSIG stainless steel internal components fluorocarbon FKM seat discs molded lip fabric reinforced diaphragms and large aluminum precision machined orifice to minimize freeze ups while providing superior downstream regulation and maximum.
Regulators that are installed at the tank will be either a single stage regulator high pressure regulator or integral two-stage regulator and must be protected from the elements by one of two means. 1 The regulator being shielded by means of a suitable cover such as the tank dome pictured above or 2 The regulator being installed with the vent facing down if installed without a cover. Fisher First Stage Regulators.
Marshall Excelsior First Stage Regulators. Rego First Stage Regulators. See more First Stage Regulators.
3390 Lake City Way Burnaby. First Stage Regulators Tank to Range. First stage regulators are installed at the propane tank connected directly to the service valve with a pigtail.
If a first period regulator is utilized in an LP fuel plumbing program a moment stage regulator must be setup downstream. Put differently a first period regulator cannot be setup. Marshall 1122H-AAJ First Stage Propane LP Regulator 10PSI Output 14 x 12.
10 PSI Output - 14 Female NPT Input x 12 Female NPT Output 250 PSI Max Input - Must be used in conjunction with a Second Stage Low Pressure Regulator. 8 - 12 PSI 1000000 BTU Max Output Capacity Replaces. Rego LV3403TR Fisher More Info.
What is a first-stage propane regulator. During the first stage of the propane regulator the system will compensate for differences in tank pressure and deliver propane gas at a pressure between 10 pounds and less. First-stage propane regulators have the purpose of supplying propane at the proper pressure to a downstream second-stage propane.
Two-stage propane regulators are simply a combination of first and second-stage regulators built into one unit. They are installed at the propane tank and cancels out fluctuating tank pressures at the inlet to provide constant pressure on the outlet depending on the changing appliances demands. First Stage Regulators.
First stage regulators are designed for larger-sized grills that have multiple burners. This type of regulator allows for a huge capacity of up to 200000 BTUs. It regulates the pressure of the tank and reduces it to a more suitable level for use.
The second stage regulator has a capacity of 17500. 1st Level Regulators Tank to Line. First stage regulators are installed at the propane tank connected directly to the service valve with a pigtail.
If a first phase regulator is used in an LP gasoline plumbing system an extra phase regulator must be installed downstream. To put it differently a primary stage regulator cannot be setup. Ideal for use as a first stage regulator on any domestic size ASME or DOT container in propane gas installations requiring up to 1500000 BTUs per hour.
The regulator is factory set to reduce container pressure to an intermediate pressure of approximately 10 PSIG. Compact design can be connected to a service valve using either a POL adapter. Propane regulators guidelines you need to know.
Propane regulators are manufactured for a variety of applications. Some deliver 10 psi while others deliver 11 inches of water column approximately 12 psi Also some regulators are considered adjustable medium pressure regulators and are used in special applications. Some are single stage and others are two stage.
Compact First Stage Regulators LV3403TR. Ideal for use as a first stage regulator on any domestic size ASME or DOT container in propane gas installations requiring up to 1500000 BTUs per hour. The regulator is factory set to reduce container pressure to an intermediate pressure of approximately 10 PSIG.
This is a first-stage regulator used to reduce tank pressure to a lower pressure. This regulator has a capacity of 2100000 BTUhr. Inlet is Female POL.
Outlet is 12 Female Pipe Thread FNPT. Outlet setting is 10 psig adjustable 8-12 psig.